<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0872-1904</journal-id>
<journal-title><![CDATA[Portugaliae Electrochimica Acta]]></journal-title>
<abbrev-journal-title><![CDATA[Port. Electrochim. Acta]]></abbrev-journal-title>
<issn>0872-1904</issn>
<publisher>
<publisher-name><![CDATA[Sociedade Portuguesa de Electroquímica]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0872-19042012000600001</article-id>
<article-id pub-id-type="doi">10.4152/pea.201206371</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrode]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Prasannakumar]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Manjunatha]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Nethravathi]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Suresh]]></surname>
<given-names><![CDATA[G. S.]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rajamathib]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Venkateshad]]></surname>
<given-names><![CDATA[T. V.]]></given-names>
</name>
<xref ref-type="aff" rid="A04"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,s.s.m.r.v. degree college Chemistry Research Centre ]]></institution>
<addr-line><![CDATA[Bangalore ]]></addr-line>
<country>India</country>
</aff>
<aff id="A02">
<institution><![CDATA[,St. Josephs's College Department of Chemistry Materials Research Group]]></institution>
<addr-line><![CDATA[Bangalore ]]></addr-line>
<country>India</country>
</aff>
<aff id="A03">
<institution><![CDATA[,NMKRV College for Women Department of Chemistry ]]></institution>
<addr-line><![CDATA[Bangalore ]]></addr-line>
<country>India</country>
</aff>
<aff id="A04">
<institution><![CDATA[,Kuvempu University Department of Chemistry ]]></institution>
<addr-line><![CDATA[Shimoga ]]></addr-line>
<country>India</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>11</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>11</month>
<year>2012</year>
</pub-date>
<volume>30</volume>
<numero>6</numero>
<fpage>371</fpage>
<lpage>383</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.pt/scielo.php?script=sci_arttext&amp;pid=S0872-19042012000600001&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.pt/scielo.php?script=sci_abstract&amp;pid=S0872-19042012000600001&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.pt/scielo.php?script=sci_pdf&amp;pid=S0872-19042012000600001&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[A modified electrode is fabricated by the electrodeposition of polyaniline-polystyrene sulphonate composite onto the carboxylated graphene modified graphite electrode for the detection of hydrogen peroxide (H2O2). The modified electrode displayed excellent catalytic response to the reduction of hydrogen peroxide in neutral pH. It was found that the presence of carboxylated graphene in the sensor system could effectively increase the electron transfer rate and stability. The modified electrode was characterized by cyclic voltammetry, electrochemical impedance spectroscopy and atomic force microscopy. Chronoamperometric studies showed the linear relationship between the reduction peak current and the concentration of H2O2 in the range 25 to 350 &#956;M(R =0.995) with the detection limit of 1×10-6 mol/L (S/N=3). Further, electrochemical analysis of H2O2 in the presence of common interferents such as dopamine, uric acid and ascorbic acid with the modified electrode reveals that there is no overlapping signal from the interferents.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[carboxylated graphene]]></kwd>
<kwd lng="en"><![CDATA[electropolymerizaton]]></kwd>
<kwd lng="en"><![CDATA[hydrogen peroxide]]></kwd>
<kwd lng="en"><![CDATA[polyaniline]]></kwd>
<kwd lng="en"><![CDATA[poly(styrene sulphonate)]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ 

    <p><b>Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate) - Carboxylated Graphene Modified Graphite Electrode</b></p>

    <p><b>S. Prasannakumar<sup>1</sup>, R. Manjunatha<sup>1</sup>, C. Nethravathi<sup>2</sup>, G. S. Suresh<sup>1,3,<a href="#0">*<a/></sup>, M. Rajamathib<sup>2</sup> and T. V. Venkateshad<sup>4</sup></b></p>

    <p><sup>1</sup><i> Chemistry Research Centre, S.S.M.R.V. Degree College, Jayanagar, Bangalore-560041, India</i></p>

    <p><sup>2</sup><i> Materials Research Group, Department of Chemistry, St. Josephs's College, 36 Lalbagh Road, Bangalore-560027, India</i></p>

    <p><sup>3</sup><i> Department of Chemistry, NMKRV College for Women, Jayanagar, Bangalore-560011, India</i></p>

    <p><sup>4</sup><i> Department of Chemistry, Kuvempu University, Jnanasahyadri, Shimoga-577451, India</i></p>


<!--     <p>&nbsp;</p>
    <p>doi: 10.4152/pea.201206371</p> -->


    <p>&nbsp;</p>
    ]]></body>
<body><![CDATA[<p><b>Abstract</b></p>

    <p>A modified electrode is fabricated by the electrodeposition of polyaniline-polystyrene 
sulphonate composite onto the carboxylated graphene modified graphite electrode for 
the detection of hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>). The modified electrode displayed excellent 
catalytic response to the reduction of hydrogen peroxide in neutral pH. It was found that 
the presence of carboxylated graphene in the sensor system could effectively increase 
the electron transfer rate and stability. The modified electrode was characterized by 
cyclic voltammetry, electrochemical impedance spectroscopy and atomic force 
microscopy. Chronoamperometric studies showed the linear relationship between the 
reduction peak current and the concentration of H<sub>2</sub>O<sub>2</sub> in the range 25 to 350 &mu;M(R =0.995) 
with the detection limit of 1&times;10<sup>-6</sup> mol/L (S/N=3). Further, electrochemical 
analysis of H<sub>2</sub>O<sub>2</sub> in the presence of common interferents such as dopamine, uric acid 
and ascorbic acid with the modified electrode reveals that there is no overlapping signal 
from the interferents.</p>

    <p><b><i>Keywords:</i></b> carboxylated graphene, electropolymerizaton, hydrogen peroxide, 
polyaniline, poly(styrene sulphonate).</p>


    <p>&nbsp;</p>
    <p><b>Introduction</b></p>

    <p>Graphene has been considered as one of the thinnest materials in our universe 
[1]. Graphene, a 2-D, single layer of carbon atoms with a hexagonal arrangement 
of sp 2 hybridization has attracted a tremendous amount of interest among 
researchers. It can be seen as the basic building block for graphitic materials. The 
characteristic properties of graphene include fast electron transportation, high 
thermal conductivity, excellent mechanical strength and good biocompatibility. 
The promising properties together with the ease of processibility and 
functionalizability make graphene-based materials ideal candidates for the 
application in many areas including electrochemical sensing and biosensing of 
analytes like dopamine, ascorbic acid, uric acid and NADH [2-4]. Graphenebased 
electrodes have been shown to exhibit excellent electron transfer 
promoting ability for some enzyme-based biosensors [1, 5]. Although the poor 
solubility of graphene essentially makes it difficult to construct graphene based 
electronic devices, considerable efforts have been made to accomplish the above 
purposes. The oxidation procedure used for purification of graphene, mainly to 
remove metal catalysts and amorphous carbon, also results in partial oxidation of 
the carbon atom to produce oxygen containing carboxylic acid groups in the open 
end of the graphene [4]. These groups are negatively charged in aqueous solution 
and can interact with positively charged polyelectrolyte.</p>

    <p>Electrically conducting polymer has attracted attention for application in various 
electrochemical devices including capacitors, photovoltaic cells, batteries and 
biosensors [6-8]. Polyaniline is one of the most widely used conducting polymers 
due to its easy synthesis, environment stability and simple acid/base dopingdedoping 
chemistry. Polyaniline reveals redox functionality only in acidic media; 
this feature limits its use. Incorporating polyanions into the polymer, switches the 
redox activity of the polyaniline to neutral pH [9]. It is well known that sensor 
and biosensors arrays based on polyaniline possess superior transducing ability 
and excellent interface-free performance characteristics. These sensors have been 
tested for the assay of glucose, urea, and ascorbic acid [10-12]. On the other hand 
the positively charged polyaniline can be electrodeposited on negatively charged 
carboxylated graphene effectively.</p>

    <p>The detection of hydrogen peroxide has attracted considerable attention because 
it plays an important role in food industry, clinical diagnosis and environmental 
monitoring. The hydrogen peroxide detection is also of special interest in terms 
of tracking many biological targets such as glucose and lactose. Many 
techniques have been employed for the determination of H<sub>2</sub>O<sub>2</sub>, such as titrimetry, 
spectrometry and chemiluminescence [13]. Among the various analytical 
techniques, electrochemical enzyme biosensor is the most tempting due to its 
simplicity, high selectivity of the biological recognition elements and high 
sensitivity of electrochemical transduction process [14-16]. However, the 
instability of enzyme activity, due to factors such as temperature, pH and oxygen 
restricts the use of enzyme-based sensors [17]. Various electrodes are fabricated 
for the determination of H<sub>2</sub>O<sub>2</sub> without enzymes, few to cite [18-20] 
This paper demonstrates a facile approach for developing an enzyme-less H<sub>2</sub>O<sub>2</sub> 
sensor based on electro polymerized polyaniline-polystyrene sulphonate (PANIPSS) 
composite on carboxylated graphene modified graphite electrode in 0.1 M 
phosphate buffer solution at pH 7.0. The electrochemical behavior of the 
modified electrode towards the determination of H<sub>2</sub>O<sub>2</sub> was investigated by cyclic 
voltammetry, electrochemical impedance spectroscopy and 
chronoamperommetry.</p>


    <p>&nbsp;</p>
    <p><b>Experimental details</b></p>

    ]]></body>
<body><![CDATA[<p><b><i>Reagents</i></b></p>

    <p>Hydrogen peroxide 30% (w/v) and aniline were procured from SRL India. 
Polystyrenesulphonate (PSS) (Mw: 70,000), ascorbic acid, dopamine and uric 
acid were purchased from Sigma Aldrich and used as received. Phosphate buffer 
saline (PBS) was prepared using stock solutions of 0.1 M K2HPO4, 0.1 M 
KH2PO4 and 0.1 M KCl. The pH was adjusted using 0.1 M HCl and 0.1 M 
NaOH. All other chemicals used were of analytical grade and used without 
further purification. All solutions were prepared with milli-Q water.</p>


    <p><b><i>Electrochemical measurements</i></b></p>

    <p>Cyclic voltammetry, chronoamperometry, and electrochemical impedance 
spectroscopy were carried out with Versastat 3 (Princeton applied research, 
USA). All electrochemical measurements were carried out in a three electrode 
electrochemical cell with Gr/(PANI-PSS) or Gr/carboxylated graphene-(PANIPSS) 
electrode as working electrode, saturated calomel (SCE) as reference 
electrode and platinum as auxiliary electrode.</p>


    <p><b><i>Preparation of carboxylated graphene</i></b></p>

    <p>Graphene sheets were first prepared by solvothermal reduction of colloidal 
suspension of graphite oxide according to the procedure described elsewhere 
[21]. In brief, graphite powder was added to cold and concentrated H<sub>2</sub>SO<sub>4</sub>. 
KMnO<sub>4</sub> was added with stirring and cooling. The temperature was increased to 
35 &deg;C and the mixture was maintained at this temperature for 30 minutes. Pure 
water was then added and the temperature was increased to 98 &deg;C; the mixture 
was maintained at that temperature for 15 minutes. The reaction was terminated 
by adding pure water followed by 30% H<sub>2</sub>O<sub>2</sub> solution. The resulting product is 
graphite oxide (GO). GO thus obtained was dispersed in water and the colloidal 
dispersion was subjected to solvothermal reduction in a teflon-lined stainless 
steel autoclave at 200 &deg;C to form graphene sheets. The conductivity of the 
graphene oxide (graphite oxide) is much lesser than that of reduced graphene 
oxide (graphene) (graphene oxide sheets reduced to obtain a high conductive 
graphene sheets). Graphene oxide showed a resistivity of about 188-413 k&Omega;/m 
[22]. However, the resistivity decreases drastically to ~15 k&Omega;/m after high 
thermal reduction with alcohol. Similarly electrical conductivity of graphene is 
10,000 fold increased after reduction of graphene oxide [23]. Graphene sheets 
thus obtained were refluxed with concentrated HNO3 for 5 h so that COO<sup>-</sup> is 
introduced at the edges of graphene sheet and the product obtained is hence forth 
referred to as carboxylated graphene. The carboxylated graphene was 
characterized by FTIR and pXRD and reported in our previous paper [4].</p>


    <p><b><i>Fabrication of Gr/carboxylated graphene-(PANI-PSS) electrode</i></b></p>

    <p>An electrode was made by inserting a graphite cylinder of 6 mm diameter in the 
hole of a Teflon bar with the same internal diameter. Electrical contact was made 
with a copper wire through the centre of the Teflon bar. Prior to the modification, 
the graphite electrode was polished to get a mirror shining surface using different 
grades of emery paper, i.e., 1000, 800, 6/0, 4/0 and finally with 2/0. It was then 
ultrasonicated for several minutes and rinsed with milli-Q water. Carboxylated 
graphene (8 mg/mL) was dispersed in pure water. 10 &mu;L dispersion of 
carboxylated graphene was casted onto the polished graphite electrode and dried 
at ambient temperature. This electrode was dipped in 20 mL of the solution 
containing 0.025 M aniline and 15 mg/mL polystyrene sulphonate in 0.025 M 
H<sub>2</sub>SO<sub>4</sub> and subjected to electrochemical polymerization by continuous potential 
cycling in the potential range of -0.2 to 0.8 V. A green colour deposit was seen 
on the surface of the electrode. After polymerization, Gr/carboxylated graphene(
PANI-PSS) electrode (modified electrode) was washed with water and stored in 
PBS of pH 7 when not in use.</p>


    <p><b>Results and Discussion</b></p>

    <p><b><i>Influence of carboxylated graphene dispersion and the aniline solution on 
sensor fabrication</i></b></p>

    ]]></body>
<body><![CDATA[<p>The carboxylated graphene content is one of the crucial factors to be considered 
for the development of H<sub>2</sub>O<sub>2</sub> sensor. We compared the calibration plots for H<sub>2</sub>O<sub>2</sub> 
at different electrodes by adjusting the content of the carboxylated graphene in 
the dispersion. <a href="#f1">Fig. 1</a> shows the graphite electrodes modified with carboxylated 
graphene with varying the concentration of graphene in phosphate buffer solution 
at -0.18 V towards the reduction of H<sub>2</sub>O<sub>2</sub>.</p>

    <p>&nbsp;</p>
<a name="f1">
<img src="/img/revistas/pea/v30n6/30n6a01f1.jpg">
    
<p>&nbsp;</p>

    <p>The sensitivity and cathodic current increased with carboxylated graphene 
loading from 2 to 8 mg/mL. When we increased the concentration further the 
sensitivity and cathodic current increased slightly, but the stability of the 
carboxylated film was rather poor. Hence 8 mg/mL were selected for all our 
experiments. Aniline concentration of 0.025 M was selected for all our 
experiments. This is because, when the concentration of aniline went beyond 
0.025 M, the experimental results were not satisfactory. This could be due the 
polyaniline film formed which seemed to be thick with the decreased sensitivity 
and increased response time.</p>

    <p><b><i>Electrodepositon of PANI-PSS composite on carboxylated graphene modified 
graphite electrode</i></b></p>

    <p><a href="#f2">Fig. 2</a> shows the electrodeposition of PANI-PSS onto the carboxylated graphene 
modified graphite electrode by cyclic voltammetry. The potential was swept from 
-0.2 to 0.8 V (vs. SCE), as polyaniline is redox active within this region at acidic 
pH.</p>

    <p>&nbsp;</p>
<a name="f2">
<img src="/img/revistas/pea/v30n6/30n6a01f2.jpg">
    
<p>&nbsp;</p>

    <p>It is generally agreed that PANI exists in three different base forms: 
leucoemeraldine (LEB, fully reduced), emeraldine (EB, half-oxidised) and 
pernigraniline (PNB, fully oxidized). The only electrically conducting form is, 
however, the emeraldine salt form (ES), which is the protonated form of EB. The 
CV is typical for PANI-emeraldine salt (ES) with the main peaks A and B 
corresponding to the transformation of leucoemeraldine base (LB) to ES and ES 
to pernigraniline salt (PS), respectively. On the reverse scan, peaks B' and A' 
correspond to the conversion of PS to ES and ES to LB, respectively. The 
presence of a small redox peak around 0.35 V (C and C') is associated with the 
formation of benzoquinone and hydroquinone as the side products. It was also 
observed that the current response was increased on the subsequent scans 
indicating the formation of the polymer on carboxylated graphene modified 
graphite electrode. The thickness (d) of the deposited PANI-PSS composite film 
on Gr/carboxylated graphene was estimated from the charge necessary to convert 
the leucoemeraldine form from PANI to emeraldine form (using the area under 
the first redox process in the voltammograms). The following equation was used 
to calculate the thickness of the film [24].</p>

    <p>&nbsp;</p>
<a name="e1">
<img src="/img/revistas/pea/v30n6/30n6a01e1.jpg">
    
]]></body>
<body><![CDATA[<p>&nbsp;</p>

    <p>where, Q is the charge under first cyclic voltammetric peak, A is the area of the 
electrode (0.28  cm<sup>2</sup>), &rho; is the specific density of aniline (1.02 g / cm<sup>3</sup>), Mw is the 
molecular weight of aniline (93.13 g / Mol), z is the number of electron / aniline 
units (0.5), and F is the Faradays constant. The thickness of the film was 
estimated to be 5 &mu;m.</p>


    <p><b><i>Characterization of the Gr/carboxylated graphene-(PANI-PSS) electrode using 
cyclic voltammetry and electrochemical impedance spectroscopy</i></b></p>

    <p>The cyclic voltammetric behavior of the modified electrode after deposition of 
PANI-PSS was examined using Fe(CN)<sub>6</sub><sup>4-/3-</sup> as an electrochemical probe, as 
illustrated in <a href="#f3">Fig. 3a</a>.</p>

    <p>&nbsp;</p>
<a name="f3">
<img src="/img/revistas/pea/v30n6/30n6a01f3.jpg">
    
<p>&nbsp;</p>

    <p>The oxidation of Fe(CN)<sub>6</sub><sup>4-</sup> at Gr/PANI-PSS electrode is 
quasireversible with formal potential of 0.185 V and peak to peak separation of 
0.068 V at a scan rate of 0.005 V/s. After modification with Gr/carboxylated 
graphene-(PANI-PSS), CV shows a pair of quasireversible peaks at a formal 
potential of 0.192 V and the peak to peak separation of 0.049 V. The oxidation 
peak potential was observed at 0.215 V. In addition, the peak current on the 
modified electrode was observed to be more as compared to Gr/PANI-PSS 
electrode. This increase in the peak current on the modified electrode can be 
attributed to the increase of the effective surface area due to the graphene present 
on the surface of graphite.</p> 

    <p>Electrochemical impedance spectroscopy is an effective method for probing the 
features of surface-modified electrodes. <a href="#f3">Fig. 3b</a> shows that at Gr/(PANI-PSS) 
electrode the impedance spectrum was composed of a semicircle and a straight 
tail line. The semicircle part at high frequency corresponds to limited electron-
transfer process and the linear part at low frequency originates from the mass 
transfer limitation of Fe(CN)<sub>6</sub><sup>4-/3-</sup>. Interestingly after modifying the graphite 
electrode with carboxylated graphene and PANI-PSS the semicircle is not 
observed and only a straight line was observed suggesting the presence of 
microscopically rough and porous surface. This indicates that the impedance 
offered by modified electrode-electrolyte interface for charge transfer process is 
less when compared to the Gr/(PANI-PSS) electrode [25]. The spectra were 
fitted to equivalent Randles circuit which is shown in the inset of <a href="#f3">Fig. 3b</a>. The 
circuit includes the Ohmic resistance of the electrolytic solution (Rs), the 
Warburg impedance (Zw) resulting from the ions from electrolytic solution to the 
electrode, the double layer capacitance (C<sub>dl</sub>) and the interfacial charge transfer 
resistance (R<sub>ct</sub>). The two components R<sub>ct</sub> and C<sub>dl</sub> depend on the dielectric and 
insulating features at the interface. In the Randles circuit model, both R<sub>ct</sub> and Zw 
are in parallel to the C<sub>dl</sub>. The values of the fitting parameters of the electrode are 
summarized in <a href="#t1">Table 1</a>.</p>

    <p>&nbsp;</p>
<a name="t1">
<img src="/img/revistas/pea/v30n6/30n6a01t1.jpg">
    
<p>&nbsp;</p>

    ]]></body>
<body><![CDATA[<p>The R<sub>ct</sub> value of the Gr/carboxylated graphene-(PANIPSS) 
electrode is much smaller than that of the Gr/(PANI-PSS) electrode 
suggesting that the Gr/carboxylated graphene-(PANI-PSS) electrode was 
facilitating the easy electron transfer. Further, the C<sub>dl</sub> value for the 
Gr/carboxylated graphene-(PANI-PSS) electrode is much higher than that for the 
Gr/(PANI-PSS) electrode revealing that the ferricyanide ions can easily diffuse 
through the Gr/carboxylated graphene-(PANI-PSS) electrode layer.</p>


    <p><b><i>Electrocatalytic reduction of H<sub>2</sub>O<sub>2</sub> at Gr/carboxylated graphene-(PANI-PSS) 
electrode</i></b></p>

    <p>To investigate the electrocatalytic activity of Gr/carboxylated graphene-(PANIPSS) 
electrode, electrochemical catalytic reduction of H<sub>2</sub>O<sub>2</sub> was investigated by 
cyclic voltammetry. At unmodified carbon electrodes no reduction peak was 
observed for H<sub>2</sub>O<sub>2</sub> in the potential range 0.4 to -0.6 V, suggesting that the carbon 
electrode was inactive to the direct reduction (curve not shown). However, at 
Gr/carboxylated graphene-(PANI-PSS) electrode, <a href="#f4">Fig. 4</a> shows that the reduction 
peak current at about -0.18 V was greatly enhanced in the presence of 6 mM 
H<sub>2</sub>O<sub>2</sub>.</p>

    <p>&nbsp;</p>
<a name="f4">
<img src="/img/revistas/pea/v30n6/30n6a01f4.jpg">
    
<p>&nbsp;</p>


    <p><b><i>Effect of increasing concentration and scan rate at Gr/carboxylated graphene(PANI-PSS) electrode</i></b></p>

    <p>The cyclic voltammogram responses for a series of H<sub>2</sub>O<sub>2</sub> solution with various 
concentrations are shown in <a href="#f5">Fig. 5a</a>.</p>

    <p>&nbsp;</p>
<a name="f5">
<img src="/img/revistas/pea/v30n6/30n6a01f5.jpg">
    
<p>&nbsp;</p>


    <p>With the addition of H<sub>2</sub>O<sub>2</sub> there was an 
increase in the reduction peak current linearly. The above result indicated that 
reduction of H<sub>2</sub>O<sub>2</sub> takes place at Gr/carboxylated graphene-(PANI-PSS) 
electrode.</p>

    ]]></body>
<body><![CDATA[<p><a href="#f5">Fig. 5b</a> shows the cyclic voltammograms recorded for 6 mM H<sub>2</sub>O<sub>2</sub> solution in 
different scan rates. It is observed that by increasing the sweep rate, the peak 
potential for the reduction of H<sub>2</sub>O<sub>2</sub> shifts to more negative values. The peak 
currents for the cathodic reduction of H<sub>2</sub>O<sub>2</sub> are proportional to the square root of 
scan rate, predicting a diffusion controlled process [26]. The inset in the figure 
shows the relation between scan rate and cathodic peak current and the linear 
regression equation is given by</p>

    <p>&nbsp;</p>
<a name="e2">
<img src="/img/revistas/pea/v30n6/30n6a01e2.jpg">
    
<p>&nbsp;</p>


    <p><b><i>Chronoamperometric determination of H<sub>2</sub>O<sub>2</sub> at Gr/carboxylated graphene(PANI-PSS) electrode</i></b></p>

    <p><a href="#f6">Fig. 6a</a> shows the amperogram recorded for the Gr/carboxylated graphene(PANI-PSS) 
electrode at a working potential of -0.18 V with successive 
additions of 25 &mu;M H<sub>2</sub>O<sub>2</sub> into the 0.1 M phosphate buffer solution at pH 7.0.</p>

    <p>&nbsp;</p>
<a name="f6">
<img src="/img/revistas/pea/v30n6/30n6a01f6.jpg">
    
<p>&nbsp;</p>


    <p>The reaction occurring at the Gr/carboxylated graphene-(PANI-PSS) electrode was 
very fast, reaching a dynamic equilibrium upon each addition of the analyte with 
a response time less than 3s to reach 100% signal. Such a fast amperometric 
response time is indicative of faster charge transport on the modified electrode. A 
wide linear response range from 25 &mu;M to 350 &mu;M was observed and the linear 
regression equation is</p>

    <p>&nbsp;</p>
<a name="e3">
<img src="/img/revistas/pea/v30n6/30n6a01e3.jpg">
    
<p>&nbsp;</p>


    ]]></body>
<body><![CDATA[<p>A sensitivity of 201.4 nA/&mu;M/cm<sup>2</sup> was obtained, the detection and quantification 
limits were estimated at 0.1 &mu;M(S/N=3) and 25 &mu;M, respectively. We 
investigated the effect of interfering species commonly found in biological 
samples such as ascorbic acid, dopamine and uric acid, as shown in <a href="#f6">Fig. 6b</a>. The 
addition of H<sub>2</sub>O<sub>2</sub> to the stirred solution shows the increasing current response; 
however, the addition of interfering species such as AA (25 &mu;M), DA (25 &mu;M) 
and UA (25 &mu;M) did not show any increase in current response. The accelerated 
electron transfer reaction due to the presence of graphene and PANI-PSS 
composite allows H<sub>2</sub>O<sub>2</sub> detection at a very low potential, indicating high 
selectivity towards H<sub>2</sub>O<sub>2</sub>. Various H<sub>2</sub>O<sub>2</sub> sensors have been reported in the 
literature. However, it is very difficult to compare one sensor to other because the 
performance of the sensor is greatly dependent on the applied potential, 
supporting electrolyte, electrode material and its surface area. Different H<sub>2</sub>O<sub>2</sub> 
sensors are summarized in <a href="#t2">Table 2</a> with respect to operating conditions, 
sensitivity and the detection limit: it can be seen that the performance of the 
developed sensor is comparable to most of H<sub>2</sub>O<sub>2</sub> sensors reported in the literature 
[27-32].</p>

    <p>&nbsp;</p>
<a name="t2">
<img src="/img/revistas/pea/v30n6/30n6a01t2.jpg">
    
<p>&nbsp;</p>


    <p><b><i>Effect of pH and temperature on the behavior of Gr/carboxylated graphene(PANI-PSS) electrode</i></b></p>

    <p>The effect of pH of Gr/carboxylated graphene-(PANI-PSS) electrode was 
investigated under constant H<sub>2</sub>O<sub>2</sub> concentration (1 mM) for the range of 5.5 to 
8.0. <a href="#f7">Fig. 7a</a> shows that the current increases with increase in pH value and 
reaches a maximum value at pH 6.5.</p>

    <p>&nbsp;</p>
<a name="f7">
<img src="/img/revistas/pea/v30n6/30n6a01f7.jpg">
    
<p>&nbsp;</p>


    <p>At higher pH (7.0 to 8.0) the electrocatalytic 
activity of the electrode was decreased. Since the physiological pH value is about 
7.0, we chose pH 7.0 in the electrochemical detection of H<sub>2</sub>O<sub>2</sub>. The effect of 
temperature on the activity of the modified electrode was determined at pH 7.0.</p>

    <p>When the temperature was increased from 24 &deg;C to 40 &deg;C the response increased, 
due to faster reaction and analyte diffusion and then started to decrease. The 
temperature at which the modified electrode yielded a maximum current was 
found to be at 32 &deg;C, as shown in <a href="#f7">Fig. 7b</a>.</p>


    <p><b><i>Stability and reproducibility</i></b></p>

    ]]></body>
<body><![CDATA[<p>Long term stability is one of the most important requirements of biosensors. The 
stability of Gr/carboxylated graphene-(PANI-PSS) electrode was checked in the 
presence of 1 mM H<sub>2</sub>O<sub>2</sub> by performing amperometric experiment in 0.1 M PBS 
of pH 7 at an applied potential of -0.18 V under stirring condition for a period of 
1800 s. <a href="#f8">Fig. 8</a> shows that the decrease of current observed was only around 3% 
even in stirring condition indicating that the modified electrode is stable and 
suitable for sensor application.</p>

    <p>&nbsp;</p>
<a name="f8">
<img src="/img/revistas/pea/v30n6/30n6a01f8.jpg">
    
<p>&nbsp;</p>


    <p>The modified electrode showed an acceptable 
repeatability. The interface was prepared eight times in the same manner and 
tests were performed in 0.1 M phosphate buffer of pH 7.0. A relative standard 
deviation lower than 5% was obtained, indicating the good repeatability of the 
sensor.</p> 

    <p>Hydrogen peroxide is used as preservative or decolourant in food industry and as 
additive in production of cosmetics. To investigate the actual applicability of the 
developed biosensor Gr/carboxylated graphene-(PANI-PSS) to practical usage, 
the real sample was examined. The sample which is used in beauty salon for hair 
coloring was labeled to contain 6% w/v of H<sub>2</sub>O<sub>2</sub>. The test was carried out in 0.1 
M PBS containing different aliquots of 0.1 M of the sample by an amperometric 
method. The real samples were diluted according to working range of 
Gr/carboxylated graphene-(PANI-PSS), the current response from each real 
sample at an applied potential of -0.18 V was measured. The concentration of the 
real sample analysis was then determined by interpolation on the linear range of 
calibration curves of H<sub>2</sub>O<sub>2</sub>. The results obtained for the reduction of H<sub>2</sub>O<sub>2</sub> in 
commercial sample were compared with those of Gr/carboxylated graphene
(PANI-PSS) electrodes for standard H<sub>2</sub>O<sub>2</sub> and are tabulated in <a href="#t3">Table 3</a>; this 
provides good approval for suitability of the electrode in the development of a 
reliable reproducible biosensor.</p>

    <p>&nbsp;</p>
<a name="t3">
<img src="/img/revistas/pea/v30n6/30n6a01t3.jpg">
    
<p>&nbsp;</p>


    <p>&nbsp;</p>
    <p><b>Conclusions</b></p>

    <p>In this work, the electrocatalytic reduction of H<sub>2</sub>O<sub>2</sub> at Gr/carboxylated 
graphene(PANI-PSS) electrode was investigated. An over potential diminution is achieved 
at the modified electrode at pH 7.0 with higher electron transfer kinetics. The 
electrochemical reduction of H<sub>2</sub>O<sub>2</sub> is a diffusion controlled process. The 
modified electrode also offers stable amperometric detection of H<sub>2</sub>O<sub>2</sub> at a lower 
applied potential of -0.18 V with a linear range from 25 &mu;M to 350 &mu;M and the 
detection limit was found to be 1.0 &mu;M. The modified electrode showed 
diminished response from its interferences and the surface fouling was not 
observed during voltammetric and amperometric measurement of H<sub>2</sub>O<sub>2</sub>.</p>


    ]]></body>
<body><![CDATA[<p>&nbsp;</p>
    <p><b>References</b></p>

    <p>1. Zhou K, Zhu Y, Yang X, Luo J, Li C, Luan S. Electrochim Acta. 2010;55:3055.</p>
    <p>2. Wang Y, Li Y, Tang L, Lu J, Li J. Electrochem Comm. 2009;11:889.</p>
    <p>3. Shan C, Yang H, Han D, Zhang Q, Ivaska A, Niu L. Biosens Bioelectron. 2010;25:1504.</p>
    <p>4. Kumar SP, Manjunatha R, Nethravathi C, Suresh GS, Rajamathi M, Venkatesha TV. Electroanalysis. 2011;23:842.</p>
    <p>5. Shan C, Yang H, Han D, Zhang Q, Ivaska A, Niu L. Biosens Bioelectron. 2010;25:1070.</p>
    <!-- ref --><p>6. Taguchi S, Tanaka T. J Power Sources. 1987;20:249.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0872-1904201200060000100006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <p>7. Panero S, Prosperi P, Bonino F, Scrosati B, Corradini A, Mastragostino M. Electrochim Acta. 1987;32:1007.</p>
    ]]></body>
<body><![CDATA[<!-- ref --><p>8. Valente AJM, Burrows HD, Lobo VMM. Colloids Surf A: Physicochem Eng Aspects. 2006;275:221.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000103&pid=S0872-1904201200060000100008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <p>9. Granot E, Basnar B, Cheglakov Z, Katz E, Willer I. Electroanalysis. 2006;18:26.</p>
    <!-- ref --><p>10. Mu S, Xue H. Sens Actuat B. 1996;31:155.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0872-1904201200060000100010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <!-- ref --><p>11. Shaolin M, Jinqing K, Jianbing Z. J Electroanal Chem. 1992;334:121.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0872-1904201200060000100011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <!-- ref --><p>12. Kocherginsky NM, Wang Z. J Electroanal Chem. 2007;611:162.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0872-1904201200060000100012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <p>13. Liu X, Luo L, Ding Y, Xu Y, Li F. J Solid State Electrochem. In press. DOI: 10.1007/s10008-010-1120-y.</p>
    ]]></body>
<body><![CDATA[<p>14. Yang Y, Yang G, Huang Y, Bai H, Lu X. Colloids Surf A: Physicochem Eng Aspects. 2009;340:50.</p>
    <!-- ref --><p>15. Upadhyay AK, Ting TW, Chen SM. Talanta. 2009;79:38.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0872-1904201200060000100015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <!-- ref --><p>16. Luo X, Killard AJ, Morrin A, Smyth MR. Anal Chim Acta. 2006;575:39.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0872-1904201200060000100016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <p>17. Liu A, Dong W, Liu E, Tang W, Zhu J, Han J. Electrochim Acta. 2010;55:1971.</p>
    <p>18. Jia W, Guo M, Zheng Z, Yu T, Rodriguez EG, Wang Y, Lei Y. J Electroanal Chem. 2009;625:27.</p>
    <!-- ref --><p>19. Lo PH, Kumar SA, Chen SM. Colloids Surf B: Biointerfaces. 2008;66:266.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0872-1904201200060000100019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <p>20. Liu Z, Zhao B, Shi Y, Guo C, Yang H, Li Z. Talanta. 2010;81:1650.</p>
    ]]></body>
<body><![CDATA[<!-- ref --><p>21. Nethravathi C, Rajamathi M. Carbon. 2008;46:1994.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000123&pid=S0872-1904201200060000100021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <p>22. Su CY, Xu Y, Zhang W, Zhao J, Liu A, Tang X, Tsai CH, Huang Y., Li LJ. ACS Nano. 2010;4:5285.</p>
    <p>23. Gilje S, Han S, Wang M, Wang KL, Kaner RB. Nano Lett. 2007;7:3394.</p>
    <!-- ref --><p>24. Chen WC, Wen TCN, Gopalan A. J Electrochem Soc. 2004;151:F242.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000127&pid=S0872-1904201200060000100024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <!-- ref --><p>25. Liu A, Wei M, Honma I, Zhou H. Adv Funct Mater. 2006;16:371.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000129&pid=S0872-1904201200060000100025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <!-- ref --><p>26. Simon BP, Fabregas E. Biosens Bioelectron. 2006;22:131.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000131&pid=S0872-1904201200060000100026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    ]]></body>
<body><![CDATA[<p>27. Liu Z, Zhao B, Shi Y, Guo C, Yang H, Li Z. Talanta. 2010;81:1650.</p>
    <!-- ref --><p>28. Song MJ, Hwang SW, Whang D. Talanta. 2010;80:1648.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000134&pid=S0872-1904201200060000100028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <!-- ref --><p>29. Santhosh P, Manesh K.M, Gopalan A, Lee KP. Anal Chim Acta. 2006;575:32.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000136&pid=S0872-1904201200060000100029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <p>30. Li L, Du Z, Liu S, Hao Q, Wang Y, Li Q, Wang T. Talanta. 2010;82:1637.</p>
    <!-- ref --><p>31. Wang Q, Yun Y, Zheng J. Microchim Acta. 2009;167:153.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000139&pid=S0872-1904201200060000100031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>
    <p>32. Tan XC, Zhang JL, Tan SW, Zhao DD, Huang ZW, Mi Y, Huang ZY. Sensors. 2009;9.6185.</p>



    <p>&nbsp;</p>
    ]]></body>
<body><![CDATA[<p><b>Acknowledgements</b></p>

    <p>The authors gratefully thank Sri. A.V.S. Murthy honorary secretary, Rashtreeya 
Sikshana Samiti Trust, Bangalore, and Dr. P. Yashoda, Principal, S.S.M.R.V. Degree 
College, Bangalore, for their continuous support and encouragement. S. Prasanna 
Kumar personally thanks Fr. Roshan Lobo, Principal, St. Joseph's Pre-University 
College, Bangalore for his support and encouragement. R. Manjunatha acknowledges 
the financial support from Department of Atomic Energy - Board of Research in 
Nuclear Sciences (DAE-BRNS), Government of India.</p>


    <p>&nbsp;</p>
    <p><a name=0></a><sup><a href="#top">*</a></sup>Corresponding author. E-mail address: <a href="mailto:sureshssmrv@yahoo.co.in">sureshssmrv@yahoo.co.in</a></p>

    <p>Received 6 April 2012; accepted 16 November 2012</p>

    <p><a href="http://www.peacta.org" target="_blank">www.peacta.org</a> </p>


     ]]></body>
<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhou]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
</person-group>
<source><![CDATA[Electrochim Acta]]></source>
<year>2010</year>
<volume>55</volume>
<page-range>3055</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Tang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<source><![CDATA[Electrochem Comm]]></source>
<year>2009</year>
<volume>11</volume>
<page-range>889</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Biosens Bioelectron]]></source>
<year>2010</year>
<volume>25</volume>
<page-range>1504</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kumar]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
<name>
<surname><![CDATA[Manjunatha]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Nethravathi]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<source><![CDATA[Electroanalysis]]></source>
<year>2011</year>
<volume>23</volume>
<page-range>842</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Biosens Bioelectron]]></source>
<year>2010</year>
<volume>25</volume>
<page-range>1070</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Taguchi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Tanaka]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<source><![CDATA[J Power Sources]]></source>
<year>1987</year>
<volume>20</volume>
<page-range>249</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Panero]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Prosperi]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Bonino]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<source><![CDATA[Electrochim Acta]]></source>
<year>1987</year>
<volume>32</volume>
<page-range>1007</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Valente]]></surname>
<given-names><![CDATA[AJM]]></given-names>
</name>
<name>
<surname><![CDATA[Burrows]]></surname>
<given-names><![CDATA[HD]]></given-names>
</name>
<name>
<surname><![CDATA[Lobo]]></surname>
<given-names><![CDATA[VMM]]></given-names>
</name>
</person-group>
<source><![CDATA[Colloids Surf A: Physicochem Eng Aspects]]></source>
<year>2006</year>
<volume>275</volume>
<page-range>221</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Granot]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Basnar]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Cheglakov]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<source><![CDATA[Electroanalysis]]></source>
<year>2006</year>
<volume>18</volume>
<page-range>26</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mu]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Xue]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Sens Actuat B]]></source>
<year>1996</year>
<volume>31</volume>
<page-range>155</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shaolin]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Jinqing]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Jianbing]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<source><![CDATA[J Electroanal Chem]]></source>
<year>1992</year>
<volume>334</volume>
<page-range>121</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kocherginsky]]></surname>
<given-names><![CDATA[NM]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<source><![CDATA[J Electroanal Chem]]></source>
<year>2007</year>
<volume>611</volume>
<page-range>162</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Luo]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Ding]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<source><![CDATA[J Solid State Electrochem]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Huang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<source><![CDATA[Colloids Surf A: Physicochem Eng Aspects]]></source>
<year>2009</year>
<volume>340</volume>
<page-range>50</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Upadhyay]]></surname>
<given-names><![CDATA[AK]]></given-names>
</name>
<name>
<surname><![CDATA[Ting]]></surname>
<given-names><![CDATA[TW]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
</person-group>
<source><![CDATA[Talanta]]></source>
<year>2009</year>
<volume>79</volume>
<page-range>38</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Luo]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Killard]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Morrin]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Smyth]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
</person-group>
<source><![CDATA[Anal Chim Acta]]></source>
<year>2006</year>
<volume>575</volume>
<page-range>39</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Dong]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[Electrochim Acta]]></source>
<year>2010</year>
<volume>55</volume>
<page-range>1971</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jia]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Guo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Zheng]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<source><![CDATA[J Electroanal Chem]]></source>
<year>2009</year>
<volume>625</volume>
<page-range>27</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lo]]></surname>
<given-names><![CDATA[PH]]></given-names>
</name>
<name>
<surname><![CDATA[Kumar]]></surname>
<given-names><![CDATA[SA]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
</person-group>
<source><![CDATA[Colloids Surf B: Biointerfaces]]></source>
<year>2008</year>
<volume>66</volume>
<page-range>266</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Zhao]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Shi]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<source><![CDATA[Talanta]]></source>
<year>2010</year>
<volume>81</volume>
<page-range>1650</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nethravathi]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Rajamathi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Carbon]]></source>
<year>2008</year>
<volume>46</volume>
<page-range>1994</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Su]]></surname>
<given-names><![CDATA[CY]]></given-names>
</name>
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<source><![CDATA[ACS Nano]]></source>
<year>2010</year>
<volume>4</volume>
<page-range>5285</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gilje]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Nano Lett]]></source>
<year>2007</year>
<volume>7</volume>
<page-range>3394</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[WC]]></given-names>
</name>
<name>
<surname><![CDATA[Wen]]></surname>
<given-names><![CDATA[TCN]]></given-names>
</name>
<name>
<surname><![CDATA[Gopalan]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[J Electrochem Soc]]></source>
<year>2004</year>
<volume>151</volume>
<page-range>F242</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Wei]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Honma]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Zhou]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Adv Funct Mater]]></source>
<year>2006</year>
<volume>16</volume>
<page-range>371</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Simon]]></surname>
<given-names><![CDATA[BP]]></given-names>
</name>
<name>
<surname><![CDATA[Fabregas]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[Biosens Bioelectron]]></source>
<year>2006</year>
<volume>22</volume>
<page-range>131</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Zhao]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Shi]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<source><![CDATA[Talanta]]></source>
<year>2010</year>
<volume>81</volume>
<page-range>1650</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Song]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Hwang]]></surname>
<given-names><![CDATA[SW]]></given-names>
</name>
<name>
<surname><![CDATA[Whang]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Talanta]]></source>
<year>2010</year>
<volume>80</volume>
<page-range>1648</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Santhosh]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Manesh]]></surname>
<given-names><![CDATA[KM]]></given-names>
</name>
<name>
<surname><![CDATA[Gopalan]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[KP]]></given-names>
</name>
</person-group>
<source><![CDATA[Anal Chim Acta]]></source>
<year>2006</year>
<volume>575</volume>
<page-range>32</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Du]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<source><![CDATA[Talanta]]></source>
<year>2010</year>
<volume>82</volume>
<page-range>1637</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Yun]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Zheng]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Microchim Acta]]></source>
<year>2009</year>
<volume>167</volume>
<page-range>153</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tan]]></surname>
<given-names><![CDATA[XC]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Tan]]></surname>
<given-names><![CDATA[SW]]></given-names>
</name>
</person-group>
<source><![CDATA[Sensors]]></source>
<year>2009</year>
<volume>9</volume>
<page-range>6185</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>